25 C
Hanoi
Saturday, September 7, 2024

Installing Effective Rainscreens

- Advertisement -spot_imgspot_img
- Advertisement -spot_img

Simple, low-tech systems that can work for any type of siding

By Steve BaczekDOWNLOAD THE PDF VERSION OF THIS ARTICLE. (4.18 MB)

Most of us are all too familiar with old houses that lose heat needlessly and easily. But it was this heat loss that continually baked those houses dry and helped contribute to their continued longevity. Adding insulation and creating airtight building envelopes drastically reduces the “baking” effect in today’s houses, which makes using an effective rainscreen almost a requirement now when building a house.

Siding nails directly over commercially available rainscreen materials like this mesh.
Siding nails directly over commercially available rainscreen materials like this mesh.

A rainscreen is a system composed of a water-protection layer along with an air space behind the siding that allows excess moisture to drain away, while allowing the siding and sheathing to dry properly. Rainscreens are applied over the sheathing, and there are many materials and systems on the market that can create successful rainscreen assemblies. These include beaded or dimpled housewraps, plastic mesh material, and linear corrugated strips in metal and plastic. They are all designed to let water that gets behind the siding drain away safely. But another option that I often recommend for the homes I design is creating a rainscreen on site with the old carpenter’s standby—wood furring strips, or strapping. Strapping is inexpensive, readily available at virtually any lumber store, and easy to install.

With site-built systems, the siding nails to furring strips.
With site-built systems, the siding nails to furring strips.

In our area, strapping typically comes as 1×3 stock (2 1/2-by-3/4-inches actual). The crews usually install the strapping vertically for horizontal siding applications, letting the wood strips align with the wood-stud framing on the other side of the sheathing for a strong, long-lasting installation. The strapping we use for our rainscreen systems is not treated to avoid rot, although I’ve seen many builders who use treated 1×4 or rips of treated plywood for this application. Sometimes we paint the strapping, but that is for reasons other than avoiding rot. The reasoning behind my choice of strapping in its natural state will become clearer when we look at how this rainscreen system actually works.

Open vs. Closed Rainscreen

The rainscreens that we build with strapping can be broken down into two basic types: closed-plank systems and open-plank systems. As the name suggests, with a closed system, the siding is installed with some type of closed lap joint or simply installed as a lap siding. An open rainscreen has joints between the installed planks. Both types of systems rely on the assumption that the underlying sheathing as well as the window and door penetrations are airtight, weathertight, and properly water-managed. The siding and rainscreen are just “makeup” on the exterior of the building. But that makeup should drastically reduce the challenges and risks to the sealed building within.

With a closed rainscreen, the siding installs with a lap joint or it overlaps, as with clapboard.
With a closed rainscreen, the siding installs with a lap joint or it overlaps, as with clapboard.
In an open rainscreen, the siding nails to the furring strips with air gaps between the boards.
In an open rainscreen, the siding nails to the furring strips with air gaps between the boards.
Site-built rainscreens install over the WRB, so it should be complete with all seams and openings sealed and flashed properly.
Site-built rainscreens install over the WRB, so it should be complete with all seams and openings sealed and flashed properly.

In a closed system, the sheathing is treated normally. For sheathing with an integrated barrier, such as Zip System, the strapping installs directly over the sheathing. If the building has regular OSB or plywood sheathing with housewrap or felt paper as a WRB, the strapping installs over the WRB.

In an open rainscreen system, the gaps between the boards would allow sunlight and damaging UV rays to reach the sheathing, so that system starts with a layer of 15-lb. felt paper over the sheathing. The felt paper blocks sunlight from hitting the sheathing and degrading the WRB, while creating an effective, low-tech, and inexpensive water-shedding surface for the sheathing. The strapping then installs over the building paper.

With an open rainscreen, building paper covers the WRB to protect it from UV rays.
With an open rainscreen, building paper covers the WRB to protect it from UV rays.
Protection from critter intrusion can be mesh ...
Protection from critter intrusion can be mesh …
... or corrugated vent material.
… or corrugated vent material.

At the bottom of both types of the strapping rainscreens, the 3/4-inch space between the strapping strips lets water drain out readily, but a space like that can be an invitation to little furry friends and the like. To close it off, but still allow for drainage, I use ridge-vent mesh cut to fit and nailed in between the strapping. Another option is using manufactured corrugated plastic vents.

Multitasking Rainscreen

We’ve already discussed the fact that the air space between the strapping and behind the siding is great for draining away the bulk water. But while a rainscreen’s ability to drain water gets the biggest hype, the ventilation that these site-built systems provide is just as important. That 3/4-inch space behind the siding allows air to travel up and through the space, letting the cladding (along with the exterior sheathing based on its permeability) dry quickly from the inside.

Air space at the top of the wall allows ventilation for drying.
Air space at the top of the wall allows ventilation for drying.

With an open system, the gaps between the siding boards provide ventilation space, so that system is virtually air open. At the top of the wall in a closed system, I either vent the air spaces into the soffit (provided the soffit is part of a vented roof assembly) or devise a detail to properly vent the air space at the frieze at the top of the wall.

In a typical wall assembly, the exterior sheathing, WRB, wood lap siding, and paint finish all get wet when it rains, and the water that makes it into the assembly is temporarily stored. When the sun warms the outside surface of the siding, the drive to dry the assembly is from the inside outward. The moisture moves through the assembly relatively freely until it hits the exterior paint surface, which usually challenges the drying process. Over time, this challenge to the paint surface continues, pushing on it from within and eventually causing the paint to blister. Ultimately, the blisters break, and the paint peels. In some cases, paint failure can happen in as little as four to five years.

With the 3/4-inch strapping as the rainscreen, water also moves inward when it rains. But the water cannot bridge a 3/4-inch gap, so the majority of the water drains out of the system more quickly than with a rainscreen that is directly attached, where the surface tension of the water slows the draining process. With less moisture in the strapping system, less drying is required.

Now look at the fact that the 3/4-inch airspace also promotes ventilation, dramatically increasing the drying potential. In a rainscreen, the amount of drying is inversely proportional to the amount of wetting. So the strapping rainscreen system severely reduces the wetting problem, and at the same time, exponentially increases the speed of the drying.

Rainscreen for Other Types of Siding

Some building projects call for vertical siding, such as board and batten. In these cases, we simply lap the strapping—adding a horizontal layer over the vertical layer—to allow for the vertical orientation of the siding. In one case where part of the elevation called for corrugated metal siding, double-lapping the strapping was a perfect solution. In another project, we installed vertical siding sections above corrugated metal siding. We did not have the luxury of making those sections 3/4 inch deeper, so we simply installed the strapping on the diagonal, leaving intermittent breaks to let the water drain out below.

A second horizontal layer of furring provides nailing for vertically applied siding, such as this corrugated metal.
A second horizontal layer of furring provides nailing for vertically applied siding, such as this corrugated metal.
If there isn’t enough depth for the second layer of furring, the strips can be installed diagonally with breaks to allow water to drain down and out of the bottom.
If there isn’t enough depth for the second layer of furring, the strips can be installed diagonally with breaks to allow water to drain down and out of the bottom.

Site-built rainscreens can also work for cedar shingle siding. For the project (which was not one of mine) in the photo, the builder essentially created an aggressive skip-sheathing layer over the vertical strapping. While this particular assembly seems a bit excessive in terms of both material and labor, it does work well.

Site-built rainscreens can be used for shingle siding, but this application is labor intensive.
Site-built rainscreens can be used for shingle siding, but this application is labor intensive.

For the record, when a project calls for shingle siding, I usually specify the commercially available product that the builder is most comfortable with installing.

Open Rainscreen Detailing

As an architect, I prefer the open-plank rainscreen system for the projects that I design. While this system is tried and true from a performance standpoint, there are a couple of concerns that need to be solved for installation. We already mentioned covering the sheathing with felt paper to prevent UV exposure, which can also void the warranty of some manufacturers. To keep the strapping from being visible through the gaps between the boards, we either paint it black or cover it with a strip of black building paper. On a recent open-plank installation, the carpenters slipped in short felt-paper tabs before nailing off the tops of the boards.

Open rainscreen systems leave the furring strips exposed in the gaps between the boards. Many different strategies can be employed to hide the natural color of the strips. One option is painting the strips before they go on.
Open rainscreen systems leave the furring strips exposed in the gaps between the boards. Many different strategies can be employed to hide the natural color of the strips. One option is painting the strips before they go on.

- Advertisement -spot_imgspot_img
Latest news
- Advertisement -spot_img
Related news
- Advertisement -spot_img